Difference in forearm and upper arm blood pressure measurements in prenatal women


MCH Unit, CON-A, King Saud Bin Abdul-Aziz University for Health Sciences, King Abdul-Aziz Hospital, Ministry of National Guard Health Affairs, Al-Ahsa, Kingdom of Saudi Arabia

Correspondence Address:
Dr. Thilagavathy Ganapathy
CON-A, King Saud Bin Abdul-Aziz University for Health Sciences, King Abdul-Aziz Hospital, Ministry of National Guard Health Affairs, P. O. Box: 2477, Al-Ahsa 31982
Kingdom of Saudi Arabia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/amhs.amhs_137_18

Rights and Permissions

Background: In health-care services, when bare upper arm blood pressure (BP) measurement is impractical, the forearm may be used as a surrogate for traditional upper arm BP. Objective: This exploratory study aimed to determine the significant difference and correlation between the upper versus forearm BP measurements among low-risk prenatal women. SMaterials and Methods: A total of 156 low-risk prenatal women in the third trimester of pregnancy attending antenatal clinics at Municipal Maternity Corporation Hospitals, Bengaluru, were recruited by purposive sampling. Upper and forearm noninvasive BP (NIBP) measurements obtained by mercury sphygmomanometer, thrice at an interval of 15 min were averaged. The main outcome measures were the significant difference and correlation between the upper arm and forearm BP measurements. Results: The mean systolic BP (SBP) (117.14 ± 3.041 mmHg) and diastolic BP (DBP) (69.31 ± 8.461 mmHg) in the forearm was significantly higher than the upper arm SBP (111.72 ± 5.53; P = 0.002) and DBP (61.46 ± 6.014 mmHg; P = 0.016). The mean difference in SBP between upper and forearm was 5.42 ± 2.016 mmHg and in DBP 7.85 ± 3.204 mmHg. Upper versus forearm BP measurements had revealed a significant positive linear correlation in SBP (r = 0.849; P = 0.013) and DBP (r = 0.816; P = 0.021) by Pearson product-moment correlation coefficient. Clinically 94 (72.31%) had a significant BP measurements difference in forearm versus upper arm by approximately 6–10 mmHg. None of the maternal characteristics were independent predictors for the mean difference in SBP and DBP measurement. Conclusion: Forearm NIBP measurements are higher than the BP obtained at the upper arm location. This must be taken into consideration whenever the forearm is used as an alternative site for the upper arm BP.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed11    
    Printed0    
    Emailed0    
    PDF Downloaded5    
    Comments [Add]    

Recommend this journal